Comprehensive Power System Studies by Akron Energy

FMEA Study for Susbtation and Electrical System
We conduct comprehensive FMEA (Failure Modes and Effects Analysis) studies for substations to enhance reliability and minimize risks. Our systematic approach identifies potential failure modes, evaluates their impact on system performance, and develops proactive measures to mitigate risks.
By addressing critical vulnerabilities, we ensure optimal functionality, safety, and compliance with industry standards. Trust Akron Energy to deliver actionable insights and robust solutions for your substation's reliability and efficiency

Relay Co Ordination and Arc Flash Studies

Power Quality Studies
Earthing Adequacy and Lightening Protection Study

Earth Adequacy Study as per IEEE 80/81 with following Scope:
- Riser Integrity
- Grid Integrity
- Ground Potential Rise (GPR)
- Step & Touch Potential Measurement
For Lighting Protection as per IEC 62305 guidelines we follow below modes:
- General Assessment
- Risk Management
- Physical Damage to Structures and Life Hazard
- Electric and Electronics systems within structures
- Health Assessment and Audit, Testing of existing LPS.
Grid Code Compliance - Grid Stability Study
In the dynamic landscape of the power sector, Grid Code Compliance (GCC) is not just a regulatory hurdle—it's the foundation of a reliable, safe, and efficient electrical network. For power producers, especially those utilizing renewable sources like solar and wind, connecting to the grid requires strict adherence to these technical specifications.
Akron® Energy Private Limited, a leader in specialized services for the power ecosystem, offers comprehensive Grid Code Compliance services to ensure your power-generating systems integrate seamlessly and operate reliably with the national and international grid standards.
Grid Codes are a set of technical rules defined by the system operator (like the Central Electricity Authority - CEA in India) that govern the connection and operation of power generating units (PGUs) and other equipment to the electricity grid.
Compliance ensures that your system:
Maintains Grid Stability: Supports the grid by controlling voltage and frequency within acceptable limits.
Fault Ride-Through Capability: Stays connected and operational during short-term electrical faults.
Power Quality: Does not inject excessive harmonics or issues that degrade the quality of power for other users.
Protection and Safety: Meets all safety and protection standards to prevent damage to equipment and the overall grid.